Current Clamp PCE-PCM 3

Views: 2113

$0.00

SKU: 2d339cf6b1fd Category:

Description

Current clamp PCE-PCM 3
Digital multimeter for single-phase measurement / NCV measurement / W / VA / Var /
Inrush Current / 1000 A AC Current Measurement / Bluetooth Interface / Frequency Measurement /
Backlight / Voltage measurement / 750 kW power 

With the current clamp AC currents of up to 1000 A AC can be measured easily. At the same time, voltages of up to 1000V AC / DC can be measured with the current clamp. Thus, with the power current clamp, apparent power, reactive power and active power measurements up to 750 KW are possible. Another function of the current clamp is the measurement of the inrush current. Many consumers have a tremendously high current at the moment of switch-on. With a conventional current clamp such a measurement is not possible. For the current clamp this is not a problem.
With the NCV (Not Connected Voltage) function of the current clamp, it can be checked whether a voltage is applied to a line without performing a contacting measurement. This makes the work much easier for the user thanks to the current clamp. In addition to the measuring function, the current clamp can also be connected to a terminal via the Bluetooth interface. Via this Bluetooth interface, the measured data can be transmitted directly from the current clamp to the terminal, where it can be logged, analyzed and sent.

– Apparent / active / reactive power
– Measurement up to the 20th harmonic
– “Not Connected Voltage” function
– Inrush current measurement
– Current measurement up to 1000 A AC
– Bluetooth interface




Specification

Ambient conditions 23°C / 73.4°F ± 5°C / 41°F, < 75% RH

Measuring function    
Current measurement AC    
Measuring range Resolution Accuracy
60 A 0.01 A ± 2% + 8 Dgt
600 A 0.1 A ± 2% + 8 Dgt
1000 A 1 A ± 2% + 8 Dgt
     
Maximum input current: 1000 A AC
Frequency range: 40 …. 400 Hz
     
Measuring function    
Inrush current AC    
Measuring range Resolution Accuracy
60 A 0.01 A For reference only
600 A 0.1 A ± 5% + 60 Dgt
1000 A 1 A ± 5% + 60 Dgt
     
Integral time: 100 ms  
Measuring range: 20 … 1000 A  
Frequency range: 40 …. 400 Hz
     
Measuring function    
Voltage measurement DC    
Measuring range Resolution Accuracy
6V 0.001V ± 0.5% + 5 Dgt
60V 0.01V ± 0.5% + 5 Dgt
600V 0.1V ± 0.5% + 5 Dgt
1000V 1V ± 0.8% + 4 Dgt
     
Input impedance: 10 MΩ
Maximum input voltage: 750V AC (rms value) or 1000V DC
     
Measuring function    
Voltage measurement AC    
Measuring range Resolution Accuracy
6V 0.001V ± 0.6% + 4 Dgt
60V 0.01V ± 0.6% + 4 Dgt
600V 0.1V ± 0.6% + 4 Dgt
1000V 1V ± 0.8% + 4 Dgt
     
Input impedance: 10 MΩ
Maximum input voltage: 750V AC (rms value) or 1000V DC
Frequency range: 40 … 400 Hz
     
Measuring function    
Frequency measurement with    
The current measuring function    
Measuring range Resolution Accuracy
99.99 Hz 0.01 Hz ± 1.5% + 5 Dgt
999.9 Hz 0.1 Hz ± 1.5% + 5 Dgt
     
Measuring range: 10 … 1 kHz
Measuring range of the input signal: > 20 AAC (rms value)
The input current increases with the measuring frequency.
Maximum input current: 1000 AAC (rms value)
     
Measuring function    
Frequency measurement with the    
Voltage measurement function    
Measuring range Resolution Accuracy
99.99 Hz 0.01 Hz ± 1.5% + 5 Dgt
999.9 Hz 0.1 Hz ± 1.5% + 5 Dgt
9,999 kHz 0.001 kHz ± 1.5% + 5 Dgt
     
Measuring range: 10 … 10 kHz
Measuring range of the input signal: > 1V AC (rms value)
The input current increases with the measuring frequency.
Maximum input voltage: 1000V AC (rms value)
     
Measuring function    
Frequency measurement     
Measuring range Resolution Accuracy
9,999 Hz 0.001 Hz ± 0.3% + 5 Dgt
99.99 Hz 0.01 Hz ± 0.3% + 5 Dgt
9,999 kHz 0.1 Hz ± 0.3% + 5 Dgt
999.9 Hz 0.001 kHz ± 0.3% + 5 Dgt
99.99 kHz 0.01 kHz ± 0.3% + 5 Dgt
999.9 kHz 0.1 kHz ± 0.3% + 5 Dgt
9,999 MHz 0.001 MHz ± 0.3% + 5 Dgt
     
Overvoltage protection: 1000V DC or 750V AC (rms value)
Range of voltage input> 2V
(as the input voltage increases, so does the frequency)
     
Measuring function    
Duty cycle    
Measuring range Resolution Accuracy
0.1 … 99.9% 0.1% ± 0.3% + 5 Dgt
     
Frequency range: 10 … 10 kHz
Voltage range: 2 … 250V AC (rms value)
(The voltage increases with the frequency)
 
Duty cycle with the Frequency range: 10 … 1 kHz
Current measurement function Input current: 20 … 1000 AAC (rms value)
 
Duty cycle with the Frequency range: 10 … 1 kHz
Voltage measurement function Input current: 1 … 750V AC (rms value)
  Input impedance: 1MΩ
     
Measuring function    
Resistivity    
Measuring range Resolution Accuracy
600 Ω 0.1 Ω ± 0.8% + 3 Dgt
6 kΩ 0.001 kΩ ± 0.8% + 3 Dgt
60 kΩ 0.01 kΩ ± 0.8% + 3 Dgt
600 kΩ 0.1 kΩ ± 0.8% + 3 Dgt
6 MΩ 0.001 MΩ ± 2% + 5 Dgt
60 MΩ 0.1 MΩ ± 2% + 5 Dgt
     
Measuring voltage: approx. 0.78V
Overvoltage protection: 750V DC, 1000V AC (rms value)
     
Measuring function    
Continuity test    
Measuring range Resolution Accuracy
600 Ω 0.1 Ω
     
Acoustic signal at < 50 Ω
Test voltage: 1.48V
Overvoltage protection: 750V DC, 1000V AC (rms value)
     
Measuring function    
Capacitance measurement    
Measuring range Resolution Accuracy
9.999 nF 0.001 nF ± 3% + 5 Dgt
99.99 n.f. 0.01 nF ± 3% + 5 Dgt
999.9 nF 0.1 nF

Delivery Scope

1 x Current clamp PCE-PCM 3
1 x Transport bag
1 x Test lead set
1 x 9V block battery
1 x User manual